PlanningConsider Site Conditions

Consider Site Conditions

Consider the site conditions to ensure you get the most out of your settlement monitoring scheme.

Protection of the ASP

The ASP is designed and built to be robust, with the construction environment in mind. However there are some sources of force that must be considered when planning the installation:

Where the host material for the ASP contains large aggregate, rocks or other large debris, the ASP should be protected to avoid point loading or piercing.

This can be achieved by installing within a trench backfilled with a clean fill such as sand or other filtered material, as described in the Installation Guide section.

Risks Posed to Site by ASP Installations

Seepage

The installation of the ASP – particularly when installed within a sand filled trench – can create a seepage path which may present issues where piezometers are installed nearby or in water retaining structures.

Mitigation Options:

  • Use a bentonite/sand mix to mitigate water migration

  • Install compacted bentonite plugs by using solely bentonite powder or pellets over a 2m section of the trench.

Fire

MDPE, which makes up the majority of the ASP's body, is fire enabling and therefore not suited to applications with high fire risk without appropriate measures being taken.