RecordingData Management

Data Reduction

Convert ASP sensor outputs to relative or absolute settlement

Outputs

The ASP communicates digitally via an RS485 BUS. Your data logger will recall measurements from the ASP via an ASCII protocol or MODBUS RTU.

The following provides details on each of the possible outputs:

Distance

The ASP nodes carry out onboard conversion of pressure to mm head. Change in elevation is relative to the reference sensor(s). To calculate the current elevation of a measurement node, the following calculations are used:

Change in Relative Elevation

Fixed Reference Sensor

If the elevation of the reference sensor is assumed to be fixed:

Δeₙ = Δₙ - Δᵣ

Where:

  • Δeₙ = change in relative elevation of a given node

  • Δₙ = n₁ - n₀ = current reading at node n minus initial reading at node n

  • Δᵣ = r₁ - r₀ = current reading at reference sensor, or the mean of readings from multiple reference sensors minus initial reference reading

Derived Reference

If the elevation of the reference is derived:

Δeₙ = Δₙ - Δᵣ + Δd

Where:

  • Δeₙ = change in relative elevation of a given node

  • Δₙ = n₁ - n₀ = current reading at node n minus initial reading at node n

  • Δᵣ = r₁ - r₀ = current reading at reference sensor, or the mean of readings from multiple reference sensors minus the initial reading at the reference sensor(s)

  • Δd = d₁ - d₀ = current reading of the external reference minus the initial reading

Absolute Elevation

To calculate the absolute elevation of a measurement node:

Eₙ₁ = Δeₙ + Eₙ₀

Where:

  • Eₙ₁ = Current reduced level of a given node

  • Δeₙ = change in relative elevation as described above

  • Eₙ₀ = Initial reduced level of node at time of installation

Always record initial elevations (Eₙ₀) during installation and the baseline reading period to enable accurate absolute elevation calculations.

Voltage

Voltage received by each sensor during measurement.

This provides useful troubleshooting metric, and often a better indicator of reducing battery power than the power recorded by the data logger itself.

Temperature

Temperature at each sensor in degrees Celsius.

While temperature compensation is carried out during the Distancemeasurement, the temperature reading confirms stable temperature across the system and identifies any physical issues that may be impacting the measurement performance.

Status

Numerical code indicating measurement status.

StatusOsprey Error CodeDescription
0N/AMeasurement OK
1-99Measurement Not Ready
2-98Pressure value outside threshold
3-97Sensor reports an internal error
4-96Insufficient power